This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision Next revision Both sides next revision | ||
lecture_notes:03-31-2010 [2010/04/01 18:17] galt |
lecture_notes:03-31-2010 [2010/04/02 06:12] galt |
||
---|---|---|---|
Line 2: | Line 2: | ||
**This post was copied from [[lecture_notes:Mar31|this original source location]]** | **This post was copied from [[lecture_notes:Mar31|this original source location]]** | ||
- | Nader talked about the chemistry behind 4 Sequencing Platforms : SOLiD Bioanalyzer, 454, Illumina/Solexa, and charge based detection system Now sequencing.\\ | + | Nader talked about the chemistry behind 4 Sequencing Platforms : SOLiD Bioanalyzer, 454, Illumina/Solexa, and charge perturbation detection system Now sequencing.\\ |
Sequencing workflow : Genomic DNA -> fragment -> amplification -> immobilization -> Sequencing.\\ | Sequencing workflow : Genomic DNA -> fragment -> amplification -> immobilization -> Sequencing.\\ | ||
Time required for sequencing through these platforms is :\\ | Time required for sequencing through these platforms is :\\ | ||
- | 1-2 hrs for CBD.\\ | + | 1-2 hrs for CPD.\\ |
9 hrs for 454.\\ | 9 hrs for 454.\\ | ||
3-7 days for Illumina/Solexa.\\ | 3-7 days for Illumina/Solexa.\\ | ||
Line 12: | Line 12: | ||
The underlying technolgies for the platforms :\\ | The underlying technolgies for the platforms :\\ | ||
- | * Sequencing by synthesis (SBS) : 454, Illumina/Solexa, Helicos, Pacbio, Charge based detection system Now Sequencing.\\ | + | * Sequencing by synthesis (SBS) : 454, Illumina/Solexa, Helicos, Pacbio, Charge Perturbation Detection system Now Sequencing.\\ |
* Sequencing by ligation : SOLiD.\\ | * Sequencing by ligation : SOLiD.\\ | ||
Line 65: | Line 65: | ||
There is a problem with multiple A's because of the modified nucleotides which are needed for this reaction. FIXME | There is a problem with multiple A's because of the modified nucleotides which are needed for this reaction. FIXME | ||
- | You must get the ammount of template on the beads just right. Must be all the same type. If too much template is present the read length is shortened (not sure why). If too few template is on the beads then the washing step will take away a significant amount of template and you won't have enough of a signal. | + | You must get the amount of template on the beads just right. Must be all the same type. If too much template is present the read length is shortened (not sure why). If too few template is on the beads then the washing step will take away a significant amount of template and you won't have enough of a signal. |
The packing beads that are placed around the bead which holds the template strands in the individual wells on the plate are what hold the various enzymes (other than the polymerase) needed for the reaction. | The packing beads that are placed around the bead which holds the template strands in the individual wells on the plate are what hold the various enzymes (other than the polymerase) needed for the reaction. |